The following table shows supported limits for features in the Advanced Edge License.
Note
X590, X620-X (fiber), and X690 are not supported in this version.Metric | Product | Limit |
---|---|---|
BGP auto-peering—maximum number of auto-peering nodes and VTEPs. | ExtremeSwitching, X465, X695 | 64 |
BGP auto-peering attached IPv4 hosts— maximum number of attached IPv4 hosts. | ExtremeSwitching, X465, X695 | 64,000 |
BGP auto-peering attached IPv6 hosts— maximum number of attached IPv6 hosts. | ExtremeSwitching, X465, X695 | 8,000 |
BGP
auto-peering ECMP—maximum number of equal cost multipath for
auto-peering. Note: * Subject to the limitation imposed by the number of
physical ports on a switch.
|
ExtremeSwitching, X465, X695 | 16* |
BGP auto-peering maximum IPv4 prefixes with ECMP—Maximum number of IPv4 Network prefixes with ECMP. | ExtremeSwitching, X465, X695 | 64,000 |
BGP auto-peering maximum IPv6 prefixes with ECMP—Maximum number of IPv6 Network prefixes with ECMP. | ExtremeSwitching, X465, X695 | 8,000 |
BGP auto-peering MLAG peers—maximum MLAG peers per AutoBGP node. | ExtremeSwitching, X465, X695 | 1 |
BGP auto-peering VRFs—maximum number of VRFs. | ExtremeSwitching, X465, X695 | 64 |
BGP auto-peering EVPN instances—maximum EVPN instances. | ExtremeSwitching, X465, X695 | 1,024 |
EAPS domains—maximum number of EAPS domains. Note: An EAPS ring that is being spatially reused cannot have
more than four configured EAPS domains.
|
ExtremeSwitching, X465, X695 | 128 |
ExtremeSwitching X450-G2, X460-G2 | 64 | |
ExtremeSwitching X440-G2 | 32 | |
EAPSv2 protected VLANs—maximum number of protected VLANs. | ExtremeSwitching X450-G2, X460-G2, X440-G2 | 500 |
ExtremeSwitching, X465, X695 | 2,000 | |
ERPS domains—maximum number of ERPS domains without CFM configured. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 32 |
ERPS domains—maximum number of ERPS domains with CFM configured. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 32 |
ERPSv1 protected VLANs—maximum number of protected VLANs. | ExtremeSwitching X450-G2, X460-G2, X465, X695 | 2,000 |
ExtremeSwitching X440-G2 | 1,000 | |
ERPSv2 protected VLANs—maximum number of protected VLANs. | ExtremeSwitching X450-G2, X460-G2, X465, X695 | 2,000 |
ExtremeSwitching X440-G2 | 500 | |
ESRP groups—maximum number of ESRP groups | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 32 |
ESRP domains—maximum number of ESRP domains. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 64 |
ESRP L2 VLANs—maximum number of ESRP VLANs without an IP address configured. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 1,000 |
ESRP L3 VLANs—maximum number of ESRP VLANs with an IP address configured. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 511 |
ESRP (maximum ping tracks)—maximum number of ping tracks per VLAN. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 8 |
ESRP (IP route tracks)—maximum IP route tracks per VLAN. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 8 |
ESRP (VLAN tracks)—maximum number of VLAN tracks per VLAN. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 1 |
L2 VPN: VCCV (pseudowire Virtual Circuit Connectivity Verification) VPNs per switch—maximum number of VCCV enabled VPLS VPNs. | ExtremeSwitching X460-G2, X465, X695 | 16 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
L2 VPN: VPLS MAC addresses—maximum number of MAC addresses learned by a switch. | ExtremeSwitching, X465, X695 | 140,000 |
ExtremeSwitching X460-G2 | 55,000 | |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
L2 VPN: VPLS VPNs—maximum number of VPLS virtual private networks per switch. | ExtremeSwitching X460-G2, X465, X695 | 1,023 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
L2 VPN: VPLS peers—maximum number of VPLS peers per VPLS instance. | ExtremeSwitching X460-G2, X465, X695 | 64 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
L2 VPN: LDP pseudowires—maximum number of pseudowires per switch. | ExtremeSwitching X460-G2, X465, X695 | 7,000 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
L2 VPN: static pseudowires—maximum number of static pseudowires per switch. | ExtremeSwitching X460-G2, X465, X695 | 7,000 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
L2 VPN: Virtual Private Wire Service (VPWS) VPNs—maximum number of virtual private networks per switch. | ExtremeSwitching, X465, X695 | 4,090 |
ExtremeSwitching X460-G2 | 1,023 | |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS RSVP-TE interfaces—maximum number of interfaces. | ExtremeSwitching X460-G2, X465, X695, | 32 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS RSVP-TE ingress LSPs—maximum number of ingress LSPs. | ExtremeSwitching X460-G2,, X465, X695 | 2,000 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS RSVP-TE egress LSPs—maximum number of egress LSPs. | ExtremeSwitching X460-G2, X465, X695 | 2,000 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS RSVP-TE transit LSPs—maximum number of transit LSPs. | ExtremeSwitching X460-G2, | 2,000 |
ExtremeSwitching, X465, X695 | 4,000 | |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS RSVP-TE paths—maximum number of paths. | ExtremeSwitching X460-G2 | 1,000 |
ExtremeSwitching, X465, X695 | 2,000 | |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS RSVP-TE profiles—maximum number of profiles. | ExtremeSwitching X460-G2 | 1,000 |
ExtremeSwitching, X465, X695 | 2,000 | |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS RSVP-TE EROs—maximum number of EROs per path. | ExtremeSwitching X460-G2, X465, X695 | 64 |
ExtremeSwitching X450-G2, and ExtremeSwitching X440-G2 | N/A | |
MPLS LDP peers—maximum number of MPLS LDP peers per switch. | ExtremeSwitching X460-G2, X465, X695 | 128 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS LDP adjacencies—maximum number of MPLS LDP adjacencies per switch. | ExtremeSwitching X460-G2 | 50 |
ExtremeSwitching, X465, X695 | 64 | |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS LDP ingress LSPs—maximum number of MPLS LSPs that can originate from a switch. | ExtremeSwitching X460-G2, X465, X695 | 2,048 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS LDP-enabled interfaces—maximum number of MPLS LDP configured interfaces per switch. | ExtremeSwitching X460-G2, X465, X695 | 128 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS LDP transit LSPs—maximum number of MPLS transit LSPs per switch. | ExtremeSwitching X460-G2, X465, X695 | 4,000 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS LDP egress LSPs—maximum number of MPLS egress LSPs that can terminate on a switch. | ExtremeSwitching X460-G2, X465, X695 | 4,000 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS static egress LSPs—maximum number of static egress LSPs. | ExtremeSwitching X460-G2 | 7,116 |
ExtremeSwitching, X465, X695 | 8,000 | |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS static ingress LSPs—maximum number of static ingress LSPs. | ExtremeSwitching X460-G2, X465, X695 | 4,000 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
MPLS static transit LSPs—maximum number of static transit LSPs | ExtremeSwitching X460-G2, X465, X695 | 4,000 |
ExtremeSwitching X450-G2, X440-G2 | N/A | |
OSPFv2/v3 ECMP—maximum number of equal cost multipath OSPFv2 and OSPFv3. | ExtremeSwitching X460-G2, X450-G2, X465, X695 | 64 |
ExtremeSwitching X440-G2 | N/A | |
OSPFv2 areas—as an ABR, how many OSPF areas are supported within the same switch. | ExtremeSwitching X460-G2, X465, X695 | 8 |
ExtremeSwitching X450-G2, X440-G2 | 4 | |
OSPFv2 external routes—recommended maximum number of external routes contained in an OSPF LSDB. | ExtremeSwitching, X465, X695 | 10,000 |
ExtremeSwitching X460-G2 | 5,000 | |
ExtremeSwitching X450-G2, X440-G2 | 2,400 | |
OSPFv2 inter- or intra-area routes—recommended maximum number of inter- or intra-area routes contained in an OSPF LSDB with one ABR in OSPF domain. | ExtremeSwitching, X465, X695 | 2,000 |
ExtremeSwitching X460-G2 | 2,000 | |
ExtremeSwitching X450-G2, X440-G2 | 1,000 | |
OSPFv2 inter-vr or leaking routes—recommended maximum number of inter-vr routes contained in an OSPF LSDB. | ExtremeSwitching, X465, X695, X460-G2 | 2,000 |
ExtremeSwitching X450-G2, X440-G2 | 1,000 | |
OSPFv2 interfaces—recommended maximum number of OSPF interfaces on a switch (active interfaces only). | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 4 |
OSPFv2 links—maximum number of links in the router LSA. | ExtremeSwitching X460-G2, X465, X695 | 400 |
ExtremeSwitching X450-G2, X440-G2 | 4 | |
OSPFv2 neighbors—maximum number of supported OSPF adjacencies. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 4 |
OSPFv2 routers in a single area—recommended maximum number of routers in a single OSPF area. | ExtremeSwitching, X465, X695 | 100 |
ExtremeSwitching X460-G2 | 50 | |
ExtremeSwitching X450-G2, X440-G2 | 4 | |
OSPFv2 virtual links—maximum number of supported OSPF virtual links. | ExtremeSwitching X460-G2, X465, X695 | 32 |
ExtremeSwitching X450-G2, X440-G2 | 4 | |
OSPFv3 areas—as an ABR, the maximum number of supported OSPFv3 areas. | ExtremeSwitching, X465, X695 | 100 |
ExtremeSwitching X460-G2 | 16 | |
ExtremeSwitching X450-G2, X440-G2 | 4 | |
OSPFv3 external routes—recommended maximum number of external routes. | ExtremeSwitching X460-G2, X465, X695 | 10,000 |
ExtremeSwitching X450-G2, X440-G2 | 1,200 | |
OSPFv3 inter- or intra-area routes—recommended maximum number of inter- or intra-area routes. | ExtremeSwitching, X465, X695 | 4.000 |
ExtremeSwitching X460-G2 | 3,000 | |
ExtremeSwitching X450-G2, X440-G2 | 500 | |
OSPFv3 interfaces—maximum number of OSPFv3 interfaces (active interfaces only). | ExtremeSwitching X460-G2, X450-G2, X440-G2, X465, X695 | 4 |
OSPFv3 neighbors—maximum number of OSPFv3 neighbors. | ExtremeSwitching X450-G2, X460-G2,X440-G2, X465, X695 | 4 |
OSPFv3 virtual links—maximum number of OSPFv3 virtual links supported. | ExtremeSwitching X460-G2, X465, X695 | 16 |
ExtremeSwitching X450-G2, X440-G2 | 4 | |
PIM IPv4 (maximum interfaces)—maximum number of PIM active interfaces. | ExtremeSwitching X460-G2, X450-G2,X440-G2, X465, X695 | 4 |
PIM IPv4 Limits—maximum number of multicast groups per dynamic rendezvous point. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 180 |
PIM IPv4 Limits—maximum number of multicast groups per static rendezvous point. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 3,000 (depends on policy file limits) |
PIM IPv4 Limits—maximum number of multicast sources per group. | ExtremeSwitching X460-G2, X450-G2, X465, X695 | 5,000 |
ExtremeSwitching X440-G2 | 1,500 | |
PIM IPv4 Limits—maximum number of dynamic rendezvous points per multicast group. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 145 |
PIM IPv4 Limits—static rendezvous points. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 32 |
PIM IPv6 (maximum interfaces)—maximum number of PIM active interfaces. | ExtremeSwitching X460-G2, X450-G2,X440-G2, X465, X695 | 4 |
PIM IPv6 Limits—maximum number of multicast sources per group. | ExtremeSwitching X460-G2, X465, X695 | 1,750 |
ExtremeSwitching X450-G2 | 1,500 | |
ExtremeSwitching X440-G2 | 550 | |
PIM IPv6 Limits—maximum number of multicast groups per dynamic rendezvous point. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 |
70 |
PIM IPv6 Limits—maximum number of multicast groups per static rendezvous point. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 |
3,000 (depends on policy file limits) |
PIM IPv6 Limits—maximum number of dynamic rendezvous points per multicast group. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 64 |
PIM IPv6 Limits—maximum number of secondary addresses per interface. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 70 |
PIM IPv6 Limits—static rendezvous points. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 32 |
Port-specific VLAN tags—maximum number of port-specific VLAN tags. | ExtremeSwitching X460-G2, X465 | 1,023 |
ExtremeSwitching X450-G2, X440-G2, X695 | N/A | |
Port-specific VLAN tags—maximum number of port-specific VLAN tag ports. | ExtremeSwitching X460-G2, X465 | 4,000 |
ExtremeSwitching X450-G2, X440-G2, X695 | N/A | |
VLAN Port Interfaces (VPIF)—maximum number of VLAN port interfaces. | ExtremeSwitching X460-G2 | 65,536 |
ExtremeSwitching X465, X695 | 131,585 | |
VRRP (v2/v3-IPv4)
(maximum instances)—maximum number of VRRP instances for a
single switch, with Advanced Edge license or higher. Note: These limits are applicable for Fabric Routing
configuration also.
Note: Number of groups configured should not
exceed the number of individual VRs supported (that is, in normal mode) for that platform
type.
|
Normal Mode (as individual VRs): | |
ExtremeSwitching X460-G2, X450-G2, X465, X695 | 511 | |
ExtremeSwitching X440-G2 | 128 | |
Scaled Mode (with groups): | ||
ExtremeSwitching X460-G2, X450-G2,X465, X695 |
2,048 |
|
ExtremeSwitching X440-G2 | 128 | |
VRRP (v3-IPv6) (maximum instances)—maximum number of VRRP
instances for a single switch, with Advanced Edge or Base license,
or higher. (VRRP-VRRPv3-IPv6) Note: These limits are applicable for Fabric Routing
configuration also.
Note: Number of groups configured should not
exceed the number of individual VRs supported (that is, in normal mode) for that platform
type.
|
Normal Mode (as individual VRs): | |
ExtremeSwitching X460-G2, X450-G2,X465, X695 | 511 | |
ExtremeSwitching X440-G2 | 128 | |
Scaled Mode (with groups): | ||
ExtremeSwitching X460-G2, X450-G2,X465, X695 |
2,048 |
|
ExtremeSwitching X440-G2 | 128 | |
VRRP (v2/v3-IPv4/IPv6) (maximum VRID)—maximum number of unique VRID numbers per switch. | ExtremeSwitching X460-G2, X450-G2 X440-G2,X465, X695 Note: With Advanced Edge license or higher.
|
255 |
VRRP (v2/v3-IPv4/IPv6) (maximum VRIDs per VLAN)—maximum number of VRIDs per VLAN. | ExtremeSwitching X460-G2, X450-G2 X440-G2,X465, X695 Note: With Advanced Edge license or higher.
|
255 |
VRRP (v2/v3-IPv4/IPv6) (maximum ping tracks)—maximum number of ping tracks per VLAN. | ExtremeSwitching X450-G2, X460-G2, X440-G2,X465, X695 Note: With Advanced Edge license or higher.
|
8 |
VRRP (maximum ping tracks)—maximum number of ping tracks per VRRP Instance under 128 VRRP instances, with Advanced Edge license or higher. | ExtremeSwitching X450-G2, X460-G2, X440-G2,X465, X695 | 8 (20 centisecond or 1 second hello interval) |
VRRP (v3-IPv6) (maximum ping tracks)—maximum number of ping tracks per VRRP Instance under 128 VRRP instances, with Advanced Edge license or higher. | ExtremeSwitching X450-G2, X460-G2, X440-G2,X465, X695 | 8 (20 centisecond or 1 second hello interval) |
VRRP (v2/v3-IPv4/IPv6) (maximum iproute tracks)—maximum number of IP route tracks per VLAN. | ExtremeSwitching X450-G2, X460-G2, X440-G2, X465, X695 | 8 |
VRRP (v2/v3-IPv4/IPv6)—maximum number of VLAN tracks per VLAN. | ExtremeSwitching X450-G2, X460-G2, X440-G2,X465, X695 | 8 |
VXLAN—maximum virtual networks. Note: Every VPLS instance/PSTag VLAN reduces this limit by
1.
Note: Assumption is all BUM
(broadcast/unknown-unicast/multicast) FDB entries are pointing to the same set of RTEPs when
all VNETs use explicit flooding. Depends on whether all VNETs use standard or explicit and the
number of tenant VLAN ports.
|
ExtremeSwitchingX465, X695 | 2,048–4,000 |
ExtremeSwitching X460-G2, X450-G2, X440-G2 | N/A | |
VXLAN—maximum tenant VLANs plus port combinations Note: Every (VPLS/PSTag VLAN) + port reduces the limit by
1.
|
ExtremeSwitchingX465, X695 | 4,096 |
ExtremeSwitching X460-G2, X450-G2, X440-G2 | N/A | |
VXLAN—maximum static MAC to IP bindings. Note: Every FDB entry configured reduces this limit by 1.
|
ExtremeSwitchingX465, X695 | 64,000 |
ExtremeSwitching X460-G2, X450-G2, X440-G2 | N/A | |
VXLAN—maximum RTEP IP addresses | ExtremeSwitchingX465, X695 | 512 |
ExtremeSwitching X460-G2, X450-G2, X440-G2 | N/A | |
VXLAN—maximum virtual networks with dynamic learning and OSPF extensions for VXLAN | ExtremeSwitchingX465, X695 | 4,000 |
ExtremeSwitching X460-G2, X450-G2, X440-G2 | N/A | |
VXLAN—or replicator role, maximum number of attached leafs per switch. | ExtremeSwitching X465, X695 | 256 |